Medtronic, Inc.'s (JOBS) Resolute(R) Drug-Eluting Stent Maintains Strong, Sustained Efficacy and Safety in Long-Term Follow-up

Bookmark and Share

SAN FRANCISCO--(BUSINESS WIRE)--New clinical data released today at a major meeting of interventional cardiologists show strong and sustained efficacy and safety of the Resolute® Zotarolimus-Eluting Coronary Stent from Medtronic, Inc. in long-term patient follow-up.

The single-arm RESOLUTE trial (n=129) demonstrates a low, 1.6 percent cumulative rate of target lesion revascularization (TLR) – or repeat procedures to treat the previously stented portion of the vessel – with no new TLRs between two and three years of follow-up. Cumulative rates of other clinical events remained low as well, with no new myocardial infarctions or cardiac deaths after two years. In addition, the rate of stent thrombosis – the formation of rare but dangerous blood clots within the stent – remained at zero, despite only 36.6 percent of patients being maintained on dual antiplatelet therapy (aspirin and clopidogrel) at three years.

The three-year results of RESOLUTE were released at Transcatheter Cardiovascular Therapuetics (TCT) 2009, which runs Sept. 21 – 25 at San Francisco’s Moscone Center.

“RESOLUTE included patients with a high degree of complexity for an initial clinical trial of a new drug-eluting stent,” said principal investigator Prof. Ian Meredith of Monash Medical Center in Australia. “Their remarkable outcomes at three years suggest that the Resolute DES offers a durable combination of long-term safety and efficacy that bodes well for the broad range of patients we see in the challenging environment of standard clinical practice.”

Average lesion length of RESOLUTE patients was 15.5 mm, and 82 percent of the subjects had challenging B2/C lesions. In addition, 46 percent had a prior myocardial infarction (MI), and 18 percent had a prior percutaneous coronary intervention (PCI); 18 percent had diabetes; 30 percent had unstable angina; and 70 percent had a history of smoking.

The Resolute DES features Medtronic’s proprietary BioLinx™ polymer system, which was designed to minimize inflammation, to reduce thrombotic risk and to enable rapid, complete and functional healing of the treated vessel. The BioLinx system has demonstrated the same biocompatibility requirements as the phosphorylcholine (PC) polymer used in the company’s Endeavor® Zotarolimus-Eluting Coronary Stent. Compared to the PC polymer, the BioLinx system is designed to extend the duration of drug exposure in the vessel – an elution profile of potential relevance to patients whom physicians consider to be at highest risk of needing a repeat procedure. Developed by Medtronic scientists, it is the first polymer created specifically for use on a DES.

The Resolu

te DES is commercially available in more than 100 countries outside the United States, where it is limited to investigational use in an FDA-approved clinical trial called RESOLUTE US. Medtronic is collaborating with physicians around the world to complete a global clinical trial program that will enroll more than 7,500 patients worldwide, with more than 6,300 patients receiving a Resolute DES.

RESOLUTE US (n=1,399) is a large, prospective, multicenter, controlled single-arm trial with a primary endpoint of target lesion failure (TLF) at 12 months. TLF is defined as cardiac death, target vessel myocardial infarction (Q-wave or non-Q-wave), or clinically-driven TLR by percutaneous or surgical methods. Enrollment in RESOLUTE US is expected to be complete by the end of 2009. The resulting data will be used to seek FDA approval, which Medtronic expects to receive in 2012.

Medtronic CardioVascular is committed to advancing the treatment of coronary, peripheral, aortic and structural heart disease through collaboration with leading clinicians, researchers and scientists worldwide.

About Medtronic Medtronic, Inc. (www.medtronic.com), headquartered in Minneapolis, is the global leader in medical technology – alleviating pain, restoring health and extending life for millions of people around the world.

Any forward-looking statements are subject to risks and uncertainties such as those described in Medtronic’s Annual Report on Form 10-K for the year ended April 24, 2009. Actual results may differ materially from anticipated results.

Contact:

Medtronic, Inc. Public Relations: Joe McGrath, 707-591-7367 or Investor Relations: Jeff Warren, 763-505-2696

MORE ON THIS TOPIC