|
Academic/Biomedical Research
News & Jobs
|
|
|
|
|
|
|
|
|
|
|
|
|
Free Newsletters
Archive
My Subscriptions

News by Subject
News by Disease
News by Date
PLoS
Search News
Post Your News
JoVE

Job Seeker Login
Most Recent Jobs
Search Jobs
Post Resume
Career Fairs
Career Resources
For Employers

Regional News
US & Canada
Biotech Bay
Biotech Beach
Genetown
Pharm Country
BioCapital
BioMidwest
Bio NC
BioForest
Southern Pharm
BioCanada East
US Device
Europe
Asia


Company Profiles

Research Store

Research Events
Post an Event

Real Estate
Business Opportunities
|
|
|
|
|
PLoS By Category | Recent
PLoS Articles
|
|
Oncology - Pharmacology - Radiology and Medical Imaging
|
Comparison of Optical and Power Doppler Ultrasound Imaging for Non-Invasive Evaluation of Arsenic Trioxide as a Vascular Disrupting Agent in Tumors
Published:
Friday, September 28, 2012
Author:
Mustafa K. Alhasan et al.
by Mustafa K. Alhasan, Li Liu, Matthew A. Lewis, Jennifer Magnusson, Ralph P. Mason
Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and prostate PC3-luc) growing in nude mice. Bioluminescence imaging (BLI), fluorescence imaging (FLI), and Power Doppler ultrasound (PD US) were then applied to examine acute vascular disruption following administration of arsenic trioxide (ATO).
During initial tumor growth, strong correlations were found between manual caliper measured tumor volume and FLI intensity, BLI intensity following luciferin injection, and traditional B-mode US. Administration of ATO to established U87 tumors caused significant vascular shutdown within 2 hrs at all doses in the range 5 to 10 mg/kg in a dose dependant manner, as revealed by depressed bioluminescent light emission. At lower doses substantial recovery was seen within 4 hrs. At 8 mg/kg there was >85% reduction in tumor vascular perfusion, which remained depressed after 6 hrs, but showed some recovery after 24 hrs. Similar response was observed in MCF7 and PC3 tumors. Dynamic BLI and PD US each showed similar duration and percent reductions in tumor blood flow, but FLI showed no significant changes during the first 24 hrs.
The results provide further evidence for comparable utility of optical and ultrasound imaging for monitoring tumor growth, More specifically, they confirm the utility of BLI and ultrasound imaging as facile assays of the vascular disruption in solid tumors based on ATO as a model agent.
More...
|
|
|
 |
 |
|
|
|
|
|
|
|
|