BioSpace.com

Biotech and Pharmaceutical
News & Jobs
Search the Site
 
   
Biotechnology and Pharmaceutical Channel Medical Device and Diagnostics Channel Clinical Research Channel BioSpace Collaborative    Job Seekers:  Register | Login          Employers:  Register | Login  

NEWSLETTERS
Free Newsletters
Archive
My Subscriptions

NEWS
News by Subject
News by Disease
News by Date
PLoS
Search News
Post Your News
JoVE

CAREER NETWORK
Job Seeker Login
Most Recent Jobs
Browse Biotech Jobs
Search Jobs
Post Resume
Career Fairs
Career Resources
For Employers

HOTBEDS
Regional News
US & Canada
  Biotech Bay
  Biotech Beach
  Genetown
  Pharm Country
  BioCapital
  BioMidwest
  Bio NC
  BioForest
  Southern Pharm
  BioCanada East
  US Device
Europe
Asia

DIVERSITY

INVESTOR
Market Summary
News
IPOs

PROFILES
Company Profiles

START UPS
Companies
Events

INTELLIGENCE
Research Store

INDUSTRY EVENTS
Biotech Events
Post an Event
RESOURCES
Real Estate
Business Opportunities

PLoS By Category | Recent PLoS Articles
Neurological Disorders - Urology

External Urethral Sphincter Pressure Measurement: An Accurate Method for the Diagnosis of Detrusor External Sphincter Dyssynergia?
Published: Thursday, May 31, 2012
Author: Carlos H. Suzuki Bellucci et al.

by Carlos H. Suzuki Bellucci, Jens Wöllner, Flavia Gregorini, Dorothee Birnböck, Marko Kozomara, Ulrich Mehnert, Thomas M. Kessler

Background

Combined pelvic floor electromyography (EMG) and videocystourethrography (VCUG) during urodynamic investigation are the most acceptable and widely agreed methods for diagnosing detrusor external sphincter dyssynergia (DESD). Theoretically, external urethral sphincter pressure (EUSP) measurement would provide enough information for the diagnosis of DESD and could simplify the urodynamic investigation replacing combined pelvic floor EMG and VCUG. Thus, we evaluated the diagnostic accuracy of EUSP measurement for DESD.

Patients & Methods

A consecutive series of 72 patients (36 women, 36 men) with neurogenic lower urinary tract dysfunction able to void spontaneously was prospectively evaluated at a single university spinal cord injury center. Diagnosis of DESD using EUSP measurement (index test) versus combined pelvic floor EMG and VCUG (reference standard) was assessed according to the recommendations of the Standards for Reporting of Diagnostic Accuracy Initiative.

Results

Using EUSP measurement (index test) and combined pelvic floor EMG and VCUR (reference standard), DESD was diagnosed in 10 (14%) and in 41 (57%) patients, respectively. More than half of the patients presented discordant diagnosis between the index test and the reference standard. Among 41 patients with DESD diagnosed by combined pelvic floor EMG and VCUR, EUSP measurement identified only 6 patients. EUSP measurement had a sensitivity of 15% (95% CI 5%–25%), specificity of 87% (95% CI 76%–98%), positive predictive value of 60% (95% CI 30%–90%), and negative predictive value of 56% (95% CI 44%–68%) for the diagnosis of DESD.

Conclusions

For diagnosis of DESD, EUSP measurement is inaccurate and cannot replace combined pelvic floor EMG and VCUR.