|
|
|
|
|
|
|
Free Newsletters
Archive
My Subscriptions

News by Subject
News by Disease
News by Date
PLoS
Search News
Post Your News
JoVE

Job Seeker Login
Most Recent Jobs
Browse Biotech Jobs
Search Jobs
Post Resume
Career Fairs
Career Resources
For Employers

Regional News
US & Canada
Biotech Bay
Biotech Beach
Genetown
Pharm Country
BioCapital
BioMidwest
Bio NC
BioForest
Southern Pharm
BioCanada East
US Device
Europe
Asia


Market Summary
News
IPOs

Company Profiles

Companies
Events

Research Store

Biotech Events
Post an Event

Real Estate
Business Opportunities
|
|
|
|
|
PLoS By Category | Recent
PLoS Articles
|
|
Computer Science - Mathematics - Ophthalmology
|
Fast Retinal Vessel Detection and Measurement Using Wavelets and Edge Location Refinement
Published:
Monday, March 12, 2012
Author:
Peter Bankhead et al.
by Peter Bankhead, C. Norman Scholfield, J. Graham McGeown, Tim M. Curtis
The relationship between changes in retinal vessel morphology and the onset and progression of diseases such as diabetes, hypertension and retinopathy of prematurity (ROP) has been the subject of several large scale clinical studies. However, the difficulty of quantifying changes in retinal vessels in a sufficiently fast, accurate and repeatable manner has restricted the application of the insights gleaned from these studies to clinical practice. This paper presents a novel algorithm for the efficient detection and measurement of retinal vessels, which is general enough that it can be applied to both low and high resolution fundus photographs and fluorescein angiograms upon the adjustment of only a few intuitive parameters. Firstly, we describe the simple vessel segmentation strategy, formulated in the language of wavelets, that is used for fast vessel detection. When validated using a publicly available database of retinal images, this segmentation achieves a true positive rate of 70.27%, false positive rate of 2.83%, and accuracy score of 0.9371. Vessel edges are then more precisely localised using image profiles computed perpendicularly across a spline fit of each detected vessel centreline, so that both local and global changes in vessel diameter can be readily quantified. Using a second image database, we show that the diameters output by our algorithm display good agreement with the manual measurements made by three independent observers. We conclude that the improved speed and generality offered by our algorithm are achieved without sacrificing accuracy. The algorithm is implemented in MATLAB along with a graphical user interface, and we have made the source code freely available.
More...
|
|
|
 |
 |
|
|
|
|
|
|
|
|